Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation - Université de Poitiers Accéder directement au contenu
Article Dans Une Revue Clinical Physiology and Functional Imaging Année : 2012

Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation

Résumé

Summary Purpose Postexercise HRR (heart rate recovery) and HRV (heart rate variability) are commonly used to asses non‐invasive cardiac autonomic regulation and more particularly reactivation parasympathetic function. Unfortunately, the reliability of postexercise HRR and HRV remains poorly quantified and is still lacking. The aim of this study was to examine absolute and relative reliability of HRR and HRV indices used to assess postexercise cardiac parasympathetic reactivation. Methods We studied 30 healthy men, who underwent 10‐minute heart rate recording after cessation of maximal and submaximal intensity exercises. Each condition of testing was repeated twice within 5 ± 2 days after the first one. Standard indexes of HRR and HRV were computed from heart rate and RR intervals. Results We found no significant bias between repeated measures. Relative reliability was assessed with the intraclass coefficient correlation (ICC) and absolute reliability with the standard error measurement (SEM) and coefficient of variation (CV). A large range for ICC was observed for both indexes of HRR and HRV (0·12 < ICC < 0·87 and 0·14 < ICC < 0·97, respectively). The same heterogeneity was observed for absolute reliability (5% < CV < 72% for HRR parameters and 24% < CV < 141% for HRV parameters). Conclusion According to our results, ∆60 (the absolute difference between heart rate immediately at the end of exercise and after 60 s) and HFnu (High Frequency expressed in normalized unit; that is, in a percentage of LF+HF) represent the most reliable parameters. In conclusion, we found that the measures used to asses cardiac parasympathetic reactivation were characterized by large random variations and their reliability remains moderate.

Domaines

Psychologie

Dates et versions

hal-02098020 , version 1 (12-04-2019)

Identifiants

Citer

Olivier Dupuy, Saïd Mekary, Nicolas Berryman, Louis Bherer, Michel Audiffren, et al.. Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation. Clinical Physiology and Functional Imaging, 2012, 32 (4), pp.296-304. ⟨10.1111/j.1475-097X.2012.01125.x⟩. ⟨hal-02098020⟩
62 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More